ST-3212B PON Optic Power Meter
ST-3212B PON Optical Power Meter is an upgraded version of ST-3212A PON power meter. It aims at the FTTx application and maintenance which not only can be used to test and estimate the PON signals at the same time, but also the normal power measurement and fault identification. It is a useful, essential and ideal tool for the construction and maintenance of the PON projects.
Features
. Providing simultaneous measurement at all three wavelengths
(1490nm, 1550nm&1310nm )
. Burst mode measurement at 1310nm wavelength
. Large LCD screen with backlight function
. 10 minutes Auto-off function
. Six calibration wavelength available when tested as Normal OPM
(850,1300,1310,1490,1550&1625nm)
. Added VFL Function for quick and efficient fault identification
. Data upload via USB cable
. 1000 storage test records
. 10 different threshold sets;
. 3 Colors LED light Green, Yellow or Red represent 3 types of signal conditions Pass, Warn or Fail.
. Added User self-calibration function in software which used to calibrate the PON module or set the threshold value.
. Added Factory Default function in software which enable all the customersˇ setting back to the factory setting
Technical Specification
PON module:
Model |
ST-3212B |
1310 upstream measurement | |
Pass Zone(nm) |
1260~1360 |
Isolation@1490/1550(dB) |
>40 |
|
-40~+10 |
1490 downstream measurement | |
Pass Zone(nm) |
1470~1505 |
Isolation @ 1550nm(dB) |
>30 |
Isolation@ 1310nm(dB) |
>40 |
|
-40~+12 |
1550 downstream measurement | |
Pass Zone(nm) |
1535~1570 |
Isolation at 1490nm(dB) |
>40 |
Isolation at 1310nm(dB) |
>40 |
|
-40~+25 |
Measurement Accuracy | |
Connatural uncertainty(dB) |
±0.5 |
Linearity(dB) |
±0.1 |
Passing through insertion Loss(dB) |
<1.5 |
General Information | |
Detector Type |
InGaAs |
Optical Connector |
FC/SC/ST Interchangeable |
Fiber Type |
9/125um |
Display |
LCD:128*64 |
Measurement Unit |
dB/dBm/xW |
Resolution (dB) |
0.01 |
Operation Voltage(V) |
DC 3.3~5.5 |
Power Supply |
3 AA1.5V battery |
Continuously Operation time (h) |
PON Power Meter Mode:90h Normal Optical Power Meter Mode:100h VFL Mode:50h |
Operation Temperature(℃) |
-10~60 |
Storage temperature(℃) |
-25~70 |
Weight(kg) |
500g |
Note: The operation time of the battery are all for the instrument that do not turn on backlight, if the backlight turn on the operation time will be shorted.
Measurement Accuracy | |
Connatural uncertainty(dB)<ɯ:p> |
±0.25 |
Linearity(dB) |
±0.1 |
|
-70~+6 or -50~+26 |
General Information | |
Measurement Unit |
dB/dBm |
Resolution (dB) |
0.01 |
Calibration Wavelength(nm) |
850,1300,1310,1490,1550,1625 |
Detector Type |
InGaAs |
Optical Connector |
FC/SC/ST Interchangeable/2.5 universal adapter |
Fiber Type |
9/125um |
VFL