OLT-50 Intelligent Optical Loss Tester combines stabilized laser source and optical power meter which can perform automatic bidirectional loss test on single fiber with Pass/Fail assessment to offer user-friendly operation and avoid potential operational mistake. The rugged and easy-to-use OLT-50

| · FTTx/PON applicable 
 · Optical power monitoring 
· Bidirectional loss test on single fiber 
· ORL test 
· Pass/Fail assessment 
· Automatic wavelength identification 
· Remote reference value setting  
· Internal clock & fiber S/N editable 
· Storage of 1000 test records 
· Data transfer to PC via USB 
· USB power charging 
· Over 50 hours continuous operation 
· No warm-up, quick start 
· Backlight  
· Pocketsize, lightweight and easy-to-use · CE, FCC, FDA certificates![]()  | 

| 
 Model  | 
 OLT-50  | |
| 
 Stabilized Laser Source  | ||
| 
 Wavelength (【20nm)  | 
 1310/1550nm  | 
 1310/1490/1550nm  | 
| 
 Spectrum Width  | 
 ÷5nm  | |
| 
 Emitter Type  | 
 FP-LD  | |
| 
 Output Power  | 
 >-4dBm  | |
| 
 Power Stability  | 
 【0.05dB/15min; 【0.10dB/8hr@1310/1490/1550nm  | |
| 
 Output Mode  | 
 CW, 270Hz, 1KHz, 2KHz  | |
| 
 Optical Power Meter  | ||
| 
 Calibrated Wavelength(1)   | 
 850, 1300, 1310, 1490, 1550, 1625nm  | |
| 
 Power Range (dBm)  | 
 -70 ~ +10(2)  | 
 -50 ~ +27  | 
| 
 Display Unit  | 
 W/mW/レW/nW/pW/dBm/dB(REF)  | |
| 
 Detector Type  | 
 InGaAs  | |
| 
 Accuracy  | 
 【5%【0.01nW (【0.5 dB@850nm)  | 
 【5%【1nW (【0.5 dB@850nm)  | 
| 
 Resolution  | 
 0.01dB  | |
| 
 Yes (With ShinewayTech specified Stabilized Laser Source)  | ||
| 
 MOD Identification  | 
 270Hz, 1KHz, 2KHz  | |
| 
 Optical Loss Test   | ||
| 
 Link Loss Range  | 
 50dB (1550nm, 200km)  | |
| 
 Link Loss Accuracy  | 
 【0.25dB  | |
| 
 Link Loss Test Time  | 
 < 2 seconds per wavelength  | |
| 
 ORL Test (Optional)  | ||
| 
 ORL Range  | 
 0~60dB  | |
| 
 ORL Accuracy  | 
 【0.75dB@(0~50dB), 【1.5dB@(50~60dB)  | |
| 
 ORL Uncertainty  | 
 【0.5dB@20dB  | |
| 
 General Specifications  | ||
| 
 Connector  | 
 FC (Interchangeable SC, ST)  | |
| 
 Data Storage  | 
 1000 records  | |
| 
 Data Interface  | 
 USB  | |
| 
 Backlight Display  | 
 Yes  | |
| 
 Auto Off  | 
 Yes (Auto-off after 5 minutes idle)  | |
| 
 Power Supply  | 
 Lithium Battery/ AC Adapter  | |
| 
 Battery Life  | 
 Continuous operation ∶50 hours  | |
| 
 Operating Temperature  | 
 0ìC ~ 50ìC   | |
| 
 Storage Temperature  | 
 -20ìC ~ 70ìC   | |
| 
 Relative Humidity  | 
 0 ~ 95% (Non-condensing)  | |
| 
 Weight  | 
 350g  | |
| 
 Dimensions (H 】 W 】 T)  | 
 177】80】44mm   | |