MTP-1000 is a compact modular platform with up to 3 functional modules, which is specially designed for FTTx/PON applications and can meet all test requirements of installers, contractors and service operators during network installation, service activation, maintenance and troubleshooting.
Designed for Metro, Access & FTTx Networks
 Flexible wavelength configurations to meet different requirements
 FTTX in-service test (1625nm with filter)
 PON OTDR tests through splitter (≥1×64), splitter & fiber-end identifiable
 Pass-through PON Power Meter simultaneously measures Triple-play PON signals (1310/1490/1550nm)
 Visible Fault Locator fast locates    defective connectors, faults in macrobends, patch cords and patch cord panels
 Remote/local control by PC 
 Optical Connector Inspector checks connector & fiber termination for polish quality & cleanliness

Optimized Platform Performance
 Lightweight
 8.4 inch touch screen
 Excellent Man-Machine interface for easy operation
 Damp-dust-shock proof
 Knob and touchpen combination: Fast and easy handling
 Optimized power management: 7 hours continuous operation
 Fast power up with Windows CE
Flexible Test in PON Architecture 
MTP-1000 can perform real-time test anywhere in the network for FTTx/PON installation,   activation and maintenance.
| 
 Platform  | ||||||
| 
 Display  | 
 8.4 inch TFT Touch Screen (800×600)  | |||||
| 
 Connectivity  | 
 USB×2; 10/100Mbit/s RJ-45×1  | |||||
| 
 Memory  | 
 2GB  | |||||
| 
 Power Supply  | 
 Li-Ion Battery/AC Adapter  | |||||
| 
 Battery Life  | 
 7 hours continuous operation  | |||||
| 
 Weight  | 
 2.1kg (Platform only)  | |||||
| 
 Dimensions (H×W×T)  | 
 320×190×70mm (Platform only)  | |||||
| 
 OTDR Module  | 
 Wavelength (±20nm)  | 
 Dynamic Range (dB)  | 
 EDZ(m)  | 
 ADZ(m)  | ||
| 
 MOT200-20VD  | 
 1310/1550  | 
 45/43  | 
 1.5  | 
 10  | ||
| 
 MOT200-30VC  | 
 1310/1490/1550  | 
 38/37/37  | 
 1.5  | 
 12  | ||
| 
 MOT200-31VC  | 
 1310/1550/1625  | 
 38/37/37  | 
 1.5  | 
 12  | ||
| 
 MOT200-33VC  | 
 1310/1550/1650  | 
 38/37/37  | 
 1.5  | 
 12  | ||
| 
 MOT200-40VC  | 
 850/1300/1310/1550  | 
 26/32/38/36  | 
 1.6  | 
 8/9/10/12  | ||
| 
 MOT200-41VC  | 
 1310/1490/1550/1625  | 
 38/37/36/36  | 
 1.5  | 
 12  | ||
| 
 Selectable Range  | 
 1.3, 2.5, 5, 10, 20, 40, 80, 160, 240Km  | |||||
| 
 Pulse Width  | 
 5ns,10ns,30ns,100ns,300ns,1µs,2.5µs,10µs,20µs  | |||||
| 
 Averaging Time  | 
 Quick, 15s, 30s, 45s, 60s, 90s, 120s, 180s  | |||||
| 
 Emitter Type  | 
 LD  | |||||
| 
 Connector  | 
 FC/PC (Interchangeable SC, ST)  | |||||
| 
 Distance Measure Accuracy  | 
 ±(1m + 10-5×distance + sampling space)  | |||||
| 
 Attenuation Detect Accuracy  | 
 ±0.05 dB/dB  | |||||
| 
 Reflection Detect Accuracy  | 
 ±4 dB  | |||||
| 
 Visible Laser Source  | 
 Output Power ≥ -3dBm; MOD Frequency: 1Hz; Detecting Range: 5Km  | |||||
| 
 MCI100 Optical Connector Inspector Module  | ||||||
| 
 Field of View  | 
 400µm×300µm  | |||||
| 
 Resolution  | 
 ≤1.5µm  | |||||
| 
 Focusing  | 
 Manual Focus  | |||||
| 
 Hand Probe Dimensions  | 
 Ø32×175mm  | |||||
| 
 MPN200 General Loss Tester Module: PON Power Meter  | ||||||
| 
 CAL Wavelengths  | 
 1310  | 
 1490  | 
 1550  | |||
| 
 Measurement Range  | 
 -40 ~ +10dBm (1)  | 
 -40 ~ +12dBm  | 
 -40 ~ +20dBm  | |||
| 
 Spectral Passband  | 
 1310±50nm  | 
 1490±15nm  | 
 1550±10nm  | |||
| 
 Power Uncertainty  | 
 ≤ 0.5dB  | |||||
| 
 Display Resolution  | 
 0.01dB  | |||||
| 
 Insertion Loss  | 
 ≤ 1.5dB  | |||||
| 
 MPN200 General Loss Tester Module: Stabilized Laser Source  | ||||||
| 
 Wavelength  | 
 1310,1490,1550,1625nm (±20nm)  | |||||
| 
 Emitter Type  | 
 FP-LD@1310,1490,1550nm; DFB-LD@1625nm  | |||||
| 
 Output Mode  | 
 CW, 270Hz,1KHz,2KHz  | |||||
| 
 Spectrum Width  | 
 ≤5nm  | |||||
| 
 Output Power  | 
 ≥ -3dBm  | |||||
| 
 Power Stability  | 
 ±0.05dB/15min; ±0.10dB/8hr  | |||||
| 
 Connector  | 
 FC/PC (Interchangeable SC, ST)  | |||||
| 
 MPN200 General Loss Tester Module: Optical Power Meter  | ||||||
| 
 CAL Wavelength  | 
 850,1300,1310,1490,1550,1625nm  | |||||
| 
 Power Range (dBm)  | 
 -70~+10(2)  | 
 -50~+27  | ||||
| 
 Accuracy  | 
 ±5%±0.01nW (±0.5dB@850nm)  | 
 ±5%±1nW (±0.5dB@850nm)  | ||||
| 
 Detector Type  | 
 InGaAs  | |||||
| 
 MOD Identification  | 
 270,1K,2K Hz  | |||||
| 
 Resolution  | 
 0.01dB  | |||||
| 
 Connector  | 
 FC (Interchangeable SC, ST)  | |||||