Introduction |
Signal Level Measurement |
Range |
|
30dBμV~120dBμV |
Precision |
|
Level:±1.5dB(25℃+5℃)(more than 35 dBμV) ±3dB (-10℃~40℃) Scan Mode: ±2dB(25℃+5℃) |
Resolution |
|
0.1dB |
Spectrum Analysis |
Testing Span |
|
2.5MHz, 6.25 MHz, 12.5 MHz, 25 MHz, 62.5 MHz |
Scale |
|
1, 2, 5, 10 dB/grid |
Digital Channel Power |
Bandwidth |
|
0.28MHz~9.99MHz |
Center Frequency |
|
In the range of the measured |
Modulation Type |
|
QAM, QPSK |
Others |
Audio Output |
|
Built-in speaker |
Dimensions |
|
ST1151(B): 218mm×95mm×48mm ST1185(B): 190mm×80mm×152mm |
Weight |
|
ST1151(B): About 660g ST1185(B): About 1060g |
Battery |
|
3.6V 3.5AH Ni-MH battery |
Operaing Time |
|
Average 6~8 hours (Fully charged) |
Charging Time |
|
Less than 3 hours |
|
The ST-1151(B)/ST-1185(B) Signal Level Meter is designed to provide features which are most widely used and favored by professionals in CATV industry at the least cost. Key functions include measuring and displaying the amplitude at a specific frequency or any carrier as defined by the user. In addition, the peak-hold level measurement feature in the LEVEL and SPECTRUM mode can even detect the occasional disturbance. Further, Analogue channels, Digital channels (QAM) and FM channels can all be tested efficiently and effectively with high accuracy rate. It also supports C/N measurement, voltmeter function, spectrum analysis, auto-test and data logging. Overall, its functions are easy to use and can be used in a wide range of applications. As a result, its demand in the market has been consistently strong in the past. The letter "B" designation in the model type refers to its capability to provide a broader frequency range and support the return path measurement. |
|
Main Specifications |
|
|
Frequency |
Range |
|
46MHz~870MHz 5MHz~870MHz (Only for type with letter B) |
Precision |
|
±50ppm (At 25℃+5℃) |
Resolution |
|
10KHz |
Resolution Bandwidth |
|
280KHz | |