ST-2125 E1 Transmission Analyzer

ST2125 E1 Transmission Analyzer is a powerful handheld instrument, providing a scalable, future-proof solution for the testing needs of technicians involved in the installation and maintenance of E1 digital networks. It offers full-featured the error and alarm measurements you will need to verify qu

Specifications:

ST-2125 E1 Transmission Analyzer

ST2125 E1 Transmission Analyzer is a powerful handheld instrument, providing a scalable, future-proof solution for the testing needs of technicians involved in the installation and maintenance of E1 digital networks. It offers full-featured the error and alarm measurements you will need to verify quality-of-service in your networks. Plus, signal quality measurements including frequency, level, pulse shape, jitter and other functions ensure your costly, time-consuming work performed quickly and efficiently.

Basic Functions

  • HDB3 and AMI line codes
  • 75Ω (Unbalanced), 120Ω (Balanced) and high impedance line interfaces
  • Out-of-service framed/unframed testing (“TX/RX” mode):
    √2Mb/s, N×64kb/s BER testing
    √Monitoring: Signal Loss, AIS, Frame Loss, Remote Alarm, Remote MF
      Alarm, CRC MF Loss, CAS MF Loss, Pattern Loss alarms and BIT,
      Code, FAS、CRC-4、E-BIT errors
    √Clock slips measurement
  • In-service framed/unframed testing (“RX HI-Z” and “Through” mode):
    √Rx Hi-Z and through mode testing
    √Code, FAS, CRC-4 and E-BIT BER testing
    √FAS/NFAS, MFAS/NMFAS, timeslot activity monitoring
    √Timeslot data monitoring
    √Built-in 64kb/s tone channel listen capability
    √CAS and CCS signalling monitoring
  • Round trip delay measurement
  • APS delay measurement
  • PCM simulator:
    √Extensive alarm and error generation
    √Frame data Si, Sa, A, FAS, CRC-4, MFAS, NMFAS and E-BIT control and
      monitoring
    √Idle word timeslot insertion
    √VF tone generation and measurement
    √CAS and CCS signalling generation and monitoring
  • Frequency and offset measurement
  • Clock slips measurement
  • Up to ±999 ppm transmit clock deviation
  • Double E1 channels in-service monitoring  Option1
    √Double E1 channels Rx Hi-Z and through mode testing
    √Double E1 channels Code, FAS, CRC-4, E-BIT BER testing
    √Double E1 channels FAS/NFAS, CAS Multiframe, CCS timeslot 16 and
      timeslot activity monitoring
    √Double E1 channels timeslot data monitoring
    √Double E1 channels built-in 64kb/s tone channel listen capability
    √Double E1 channels CAS and CCS signalling monitoring
  • Pulse mask measurement  Option2
    √Input E1 pulse shape display
    √Pulse width measurement
    ñPulse width and amplitude ratio measurement
    √Rising edge and falling edge time measurement
    √Overshoot and undershoot ratio measurement
    √Pulse amplitude and level measurement
  • Jitter measurement  Option3
    √Peak-peak jitter measurement
    √Jitter measurement comply with O.172 filter (18-100kHz)
    √Hit seconds and hit free seconds counts
  • Level measurement  Option4
    ñPulse level real-time measurement
    √Peak-peak pulse level measurement
  • Transmit clock sourced from external clock or signal  Option1
  • Real-time transmit circuit open/short indication
  • Autoconfigure function:
    √E1 frame format auto-detection and autoconfiguration
    √BERT pattern auto-detection and autoconfiguration
    √The timeslots carried BERT pattern auto-detection and autoconfiguration
  • Real-time clock
  • BERT pattern: PRBS, Fixed Code, 16-BIT User Word
  • Error injection: Single and Fixed Rate
  • Reset the results to zero function
  • Manual and auto-timer testing
  • Self-check, keyboard and LED testing
  • TU-T G.821, G.826 and M.2100 performance analysis
  • Histograms analysis of error and alarm events
  • Upgradeable embedded software via an RS232C interface

Main Features

  • Handheld design and easy-to-use
  • Full-featured measurements to E1 signals
  • High resolution large backlit and contrast-adjustable LCD
  • Smart navigation mode displays
  • Extensive error and alarm generation, detection and indication
  • Up to 6 hours operation from a single battery charge
  • Up to 99 days continuance test performance
  • Save/Recall of up to 10 user-defined setups and results
  • Built-in NiMH rechargeable batteries and smart charger circuit
  • Can be charged with automobile cigarette lighter battery adapter
  • Test results could be uploaded, conserved by TestManagerPro
  • The stored results could be output or printed with A4-szie report form, Excel and test files

Specifications

Item

Descriptions

Internal Clock

2048Kb/s ± 10ppm

Frequency Deviation

±999ppm

Line Interfaces

75Ω (Unbalanced), 120Ω (Balanced); High Input Impedance >2KW

Line Code

HDB3, AMI

Framing

Unframed, PCM30, PCM30CRC, PCM31, PCM31CRC

Receive Sensitivity

> -43dB

Tx Clock Source

Internal, Interface and External 2MHz clock or HDB3 signal

Pulse Mask Measurement

Comply with G.703

Jitter Measurement

Comply with O.172

Frequency measurement

Accuracy: ±1Hz

Offset Measurement

Accuracy: ±1ppm
Range: -999ppm~+999ppm

VF Injection

Frequency: 200Hz~3400Hz, Step: 10Hz

Level: -60dBm~+3dBm

VF Measurement

Frequency: 200Hz~3400Hz, Accuracy: ±1Hz

Level range : -60.00dBm~+3.14dBm
-60.00dBm~-21.00dBm, accuracy: ±2.87dBm
-20.00dBm~+3.14dBm, accuracy: ±0.21dBm

Delay Measurement

Accuracy: ±1μs

Test Patterns

PRBS

223-1, 215-1, 211-1, 29-1

Fixed Code

1111, 0000, 1010

16-BIT

User Programmable Word

Alarm Indications

Signal Loss, AIS, Frame Loss, MFrame loss, Pattern Loss,
Remote Alarm, Remote MF Alarm, Errors, Clock Slip, Low Battery

Error Injection

Type: BIT, FAS, CODE, CRC4, E-BIT

Single, Fixed Rate: 10-2, 10-3, 10-4, 10-5, 10-6, 10-7

Alarm injection

AIS, Frame Loss, CAS and CRC MFrame Loss,
Remote Alarm, Remote MFrame Alarm

Performance Analysis

ITU-T G.821, G.826 and M.2100

Display

320x240 pixel backlit monochromatic LCD

Serial Port

USB Connector

Rechargeable Batteries

5×1.2V AA NiMH batteries, continuous working for 6 hours

Recharge Time

Approx. 2 hours

AC Power Adapter

Input: 100V~240VAC, 50/60Hz
Output: 12VDC /1.5A

TestManagerPro

Operating System: WIN98/ME/2000/NT/XP

Dimensions

L×W×H: 266mm × 90/144mm × 60mm

Operating Temperature

0℃~50℃

Storage Temperature

-20℃~70℃

Humidity

5%~95% non-condensing

Weight

Approx. 800g


Configurations
Standard configuration list of the E1 Transmission Analyzer:

Item

Qua

Item

Qua

E1 Transmission Analyzer

1

TestManagerPro Setup CD

1

AC Power Adapter

1

AA NiMH Rechargeable Batteries (Built-in)

5

Automobile Cigarette Lighter Battery Adapter Cable

1

Waterproof Package

1

E1 75Ω Unbalanced Test Cable

2

Quality Certificate Card

1

E1 120Ω Balanced Test Cable

1

Maintenance Card

1

USB Communication Cable

1

Packing List

1

Users Manual

1

 

 


Optional configuration list of the E1 Transmission Analyzer:

Code

Option Name

Acquired Way

Additional Accessories

Qua

Option1

Double E1 channels monitoring and E1 External Clock

Add-on Hardware and Authorized Software

Hardware Module

1

External Clock Access Cable

1

Double E1 Channels Monitoring Test Cable

2

Embedded Software and Function Control Code

1

Option2

Pulse Mask Measurement

Authorized Software

Embedded Software and Function Control Code

1

Option3

Jitter Measurement

Authorized Software

Embedded Software and Function Control Code

1

Option4

Level Measurement

Authorized Software

Embedded Software and Function Control Code

1