OLT-50 Intelligent Optical Loss Tester combines stabilized laser source and optical power meter which can perform automatic bidirectional loss test on single fiber with Pass/Fail assessment to offer user-friendly operation and avoid potential operational mistake. The rugged and easy-to-use OLT-50

| · FTTx/PON applicable
· Optical power monitoring
· Bidirectional loss test on single fiber
· ORL test
· Pass/Fail assessment
· Automatic wavelength identification
· Remote reference value setting
· Internal clock & fiber S/N editable
· Storage of 1000 test records
· Data transfer to PC via USB
· USB power charging
· Over 50 hours continuous operation
· No warm-up, quick start
· Backlight
· Pocketsize, lightweight and easy-to-use · CE, FCC, FDA certificates![]() |

|
Model |
OLT-50 | |
|
Stabilized Laser Source | ||
|
Wavelength (【20nm) |
1310/1550nm |
1310/1490/1550nm |
|
Spectrum Width |
÷5nm | |
|
Emitter Type |
FP-LD | |
|
Output Power |
>-4dBm | |
|
Power Stability |
【0.05dB/15min; 【0.10dB/8hr@1310/1490/1550nm | |
|
Output Mode |
CW, 270Hz, 1KHz, 2KHz | |
|
Optical Power Meter | ||
|
Calibrated Wavelength(1) |
850, 1300, 1310, 1490, 1550, 1625nm | |
|
Power Range (dBm) |
-70 ~ +10(2) |
-50 ~ +27 |
|
Display Unit |
W/mW/レW/nW/pW/dBm/dB(REF) | |
|
Detector Type |
InGaAs | |
|
Accuracy |
【5%【0.01nW (【0.5 dB@850nm) |
【5%【1nW (【0.5 dB@850nm) |
|
Resolution |
0.01dB | |
|
Yes (With ShinewayTech specified Stabilized Laser Source) | ||
|
MOD Identification |
270Hz, 1KHz, 2KHz | |
|
Optical Loss Test | ||
|
Link Loss Range |
50dB (1550nm, 200km) | |
|
Link Loss Accuracy |
【0.25dB | |
|
Link Loss Test Time |
< 2 seconds per wavelength | |
|
ORL Test (Optional) | ||
|
ORL Range |
0~60dB | |
|
ORL Accuracy |
【0.75dB@(0~50dB), 【1.5dB@(50~60dB) | |
|
ORL Uncertainty |
【0.5dB@20dB | |
|
General Specifications | ||
|
Connector |
FC (Interchangeable SC, ST) | |
|
Data Storage |
1000 records | |
|
Data Interface |
USB | |
|
Backlight Display |
Yes | |
|
Auto Off |
Yes (Auto-off after 5 minutes idle) | |
|
Power Supply |
Lithium Battery/ AC Adapter | |
|
Battery Life |
Continuous operation ∶50 hours | |
|
Operating Temperature |
0ìC ~ 50ìC | |
|
Storage Temperature |
-20ìC ~ 70ìC | |
|
Relative Humidity |
0 ~ 95% (Non-condensing) | |
|
Weight |
350g | |
|
Dimensions (H 】 W 】 T) |
177】80】44mm | |

